每个主机:
- 2 x Xeon CPU E5-2620 V3 @ 2.40GHz
- 256GB RAM
- 4.4 TB存储400GB为SSD
节点10.0.0.58:FAIL:CVM内存16433468 kb小于阈值24 GBNODE 10.0.0.55:FAIL:CVM内存16433468 kb小于阈值24 GBNODE 24 GBNODE 10.0.0.57:FAIL:FAIL:FAIL:CVM MOMEMOR:CVM 1643468 KB BB IS BLESH IS BLESH IS BLESS24 GBNODE 10.0.0.56:FAIL:CVM内存16433468 kb小于阈值24 GBRefer至KB 1513,以获取有关ldap_config_check的CVM_MEMORY_CHECKDETAILED信息的详细信息,请访问NOODE.0.0.56:INFO:no ldap inspeciedy:kb in no ldap inspeciedy:kb。cvm_numa_configuration_check:node 10.0.0.58:info:cvm的ldap_config_checkdetailed信息:cvm上的vcpus(8)数量大于max cores(6)per numa numa node.node.node.node 10.0.0.0.0.55:Info:大于每个numa节点的最大内核(6)。节点10.0.0.57:info:CVM上的VCPU(8)的数量大于每个numa node.node.node.0.0.0.0.56:Inmumb:number:numa numa numa numa numa nume cores(6)CVM上的VCPU(8)的最大核心(6)每个numa节点。引用到KB 3034,以获取有关CVM_NUMA_CONFIGURATION上的详细信息vm_checks的离子:我将所有内容都留为dell的默认设置。我考虑过打电话给戴尔(Dell),但我想我可能更喜欢从马的嘴里听到它。
1.这些是6核处理器,因此CVM是否可以更好地为6VCPU配置?这样他们就不必等待下一个处理器的6个内核和2个来进行指导?
2.该集群的最佳内存设置可能是什么?这是一些设置:
- 复制因子2
- 压缩
- 压缩延迟0分钟。
- 压缩空间保存了1.3 TIB
- 压缩比1.53:1
- 性能层删除
- 磁盘重复数据删除
- 在磁盘上保存空间上 -
- 在磁盘defup比率1:1
最好的答案乔恩
\n\nI'll add a bit of color here
\n
\nRE Memory
\nNCC is flagging the memory because you've got perf-tier Dedupe on, which is recommended to have 24GB of CVM memory per host for.
\n
\nInline compression is fantastic and only requires 16GB memory, so no worries there.
\n
\nRE CPU's
\nSuper, super, super long story, the elevator version is that for the longest time, our \"default\" has been 8 vCPU CVM's, but we dont RESERVE all 8 vCPU's, so the hypervisor scheduler will prioritize along with \"user\" VM's (servers, etc).
\n
\nThat NCC check was actually partially driven by me, and to be frank, it went out the door sooner than we wanted. a future NCC release (likely 2.2.2, coming out shortly) will disable this check to prevent confusion in the field.
\n
\nThat said, going forward, a future, future NCC\/NOS release will do the following
\nTurn that check back on
\nGive proper guidance on CVM sizing based on the hardware platform
\nDefaults for \"new\" imaging will take these guidances into account, so it will be good from the jump on new systems. Existing systems would need a bit of tweaking of course.
\n
\n
\n
\nBottomline: Either turn off perf tier dedupe to get rid of the first warning (or increase CVM to 24G), and ignore that CVM NUMA check for now, until the new guidance comes out","className":"post__content__best_answer"}">