Level up your Nutanix skills and get certified for free with Nutanix University Summer School! For the next two months, anyone who completes one of the following courses - whether it\u2019s online or in person - will also receive a FREE certification exam voucher.<\/span><\/p> Eligible courses:<\/strong><\/p> Enterprise Cloud Administration<\/span><\/p>\t<\/li>\t Nutanix Data Services Administration<\/span><\/p>\t<\/li>\t Nutanix End User Computing Administration<\/span><\/p>\t<\/li>\t Nutanix Database Management & Automation<\/span><\/p>\t<\/li>\t Nutanix Multicloud Automation Administration<\/span><\/p>\t<\/li><\/ul> \u00a0<\/p> Take this opportunity to invest in your career and grow your skill set.\u00a0<\/span><\/p> \u00a0<\/p> Thanks for waiting to everyone who got our sneak peek of this last week!\u00a0\ud83d\ude09<\/p> \u00a0<\/p> Terms and Conditions<\/strong><\/em><\/p> The exam voucher will be provided to you after you have completed the course. Self-paced online student\u2019s vouchers will be assigned through the Learning Plan within 24-hours after the completion of the course.<\/span><\/em><\/p>\t<\/li>\t You must complete the course between June 14, 2022 and August 16, 2022.\u00a0<\/span><\/em><\/p>\t<\/li>\t For online students, your exam voucher must be redeemed by 8\/23\/22. For instructor-led students, your exam voucher must be redeemed 6 months after you complete the course.\u00a0<\/span><\/em><\/p>\t<\/li>\t The exam voucher code can only be used once.<\/span><\/em><\/p>\t<\/li>\t You will receive one (1) NCP exam voucher for each class completed. The voucher can be used on any NCP exam.\u00a0\u00a0<\/span><\/em><\/p>\t<\/li><\/ul> \u00a0<\/p> This article was written by Karlie Beil, Customer Marketing Specialist.\u00a0<\/p><\/div><\/div><\/section> \u00a0<\/p> \u00a9\ufe0f\ufe0f\ufe0f 2022 Nutanix, Inc. \u00a0All rights reserved. Nutanix, the Nutanix logo and all Nutanix product, feature and service names mentioned herein are registered trademarks or trademarks of Nutanix, Inc. in the United States and other countries. Other brand names mentioned herein are for identification purposes only and may be the trademarks of their respective holder(s). This post may contain links to external websites that are not part of Nutanix.com. Nutanix does not control these sites and disclaims all responsibility for the content or accuracy of any external site. Our decision to link to an external site should not be considered an endorsement of any content on such a site. This post may contain express and implied forward-looking statements, which are not historical facts and are instead based on our current expectations, estimates and beliefs. The accuracy of such statements involves risks and uncertainties and depends upon future events, including those that may be beyond our control, and actual results may differ materially and adversely from those anticipated or implied by such statements. Any forward-looking statements included herein speak only as of the date hereof and, except as required by law, we assume no obligation to update or otherwise revise any of such forward-looking statements to reflect subsequent events or circumstances.<\/p> \u00a0<\/p>","id":40952,"featuredImage":"https:\/\/uploads-us-west-2.insided.com\/nutanix-us\/attachment\/78f47513-ef06-4bf4-9b57-0269259ac6da_thumb.png","label":"Blog","replyCount":0,"views":4764,"post":{"id":61291,"author":{"id":113632,"url":"\/members\/karlie-beil-113632","name":"Karlie Beil","avatar":"https:\/\/uploads-us-west-2.insided.com\/nutanix-us\/icon\/200x200\/1581aab3-bcf6-49f4-b2fb-3d11e8c010dc.png","userTitle":"Community Manager","rank":{"isBold":false,"isItalic":false,"isUnderline":false,"name":"Community Manager","color":"#0873ba"},"userLevel":2},"content":" \u00a0<\/p> Level up your Nutanix skills and get certified for free with Nutanix University Summer School! For the next two months, anyone who completes one of the following courses - whether it\u2019s online or in person - will also receive a FREE certification exam voucher.<\/span><\/p> Eligible courses:<\/strong><\/p> Enterprise Cloud Administration<\/span><\/p>\t<\/li>\t Nutanix Data Services Administration<\/span><\/p>\t<\/li>\t Nutanix End User Computing Administration<\/span><\/p>\t<\/li>\t Nutanix Database Management & Automation<\/span><\/p>\t<\/li>\t Nutanix Multicloud Automation Administration<\/span><\/p>\t<\/li><\/ul> \u00a0<\/p> Take this opportunity to invest in your career and grow your skill set.\u00a0<\/span><\/p> \u00a0<\/p> Thanks for waiting to everyone who got our sneak peek of this last week!\u00a0\ud83d\ude09<\/p> \u00a0<\/p> Terms and Conditions<\/strong><\/em><\/p> The exam voucher will be provided to you after you have completed the course. Self-paced online student\u2019s vouchers will be assigned through the Learning Plan within 24-hours after the completion of the course.<\/span><\/em><\/p>\t<\/li>\t You must complete the course between June 14, 2022 and August 16, 2022.\u00a0<\/span><\/em><\/p>\t<\/li>\t For online students, your exam voucher must be redeemed by 8\/23\/22. For instructor-led students, your exam voucher must be redeemed 6 months after you complete the course.\u00a0<\/span><\/em><\/p>\t<\/li>\t The exam voucher code can only be used once.<\/span><\/em><\/p>\t<\/li>\t You will receive one (1) NCP exam voucher for each class completed. The voucher can be used on any NCP exam.\u00a0\u00a0<\/span><\/em><\/p>\t<\/li><\/ul> \u00a0<\/p> This article was written by Karlie Beil, Customer Marketing Specialist.\u00a0<\/p><\/div><\/div><\/section> \u00a0<\/p> \u00a9\ufe0f\ufe0f\ufe0f 2022 Nutanix, Inc. \u00a0All rights reserved. Nutanix, the Nutanix logo and all Nutanix product, feature and service names mentioned herein are registered trademarks or trademarks of Nutanix, Inc. in the United States and other countries. Other brand names mentioned herein are for identification purposes only and may be the trademarks of their respective holder(s). This post may contain links to external websites that are not part of Nutanix.com. Nutanix does not control these sites and disclaims all responsibility for the content or accuracy of any external site. Our decision to link to an external site should not be considered an endorsement of any content on such a site. This post may contain express and implied forward-looking statements, which are not historical facts and are instead based on our current expectations, estimates and beliefs. The accuracy of such statements involves risks and uncertainties and depends upon future events, including those that may be beyond our control, and actual results may differ materially and adversely from those anticipated or implied by such statements. Any forward-looking statements included herein speak only as of the date hereof and, except as required by law, we assume no obligation to update or otherwise revise any of such forward-looking statements to reflect subsequent events or circumstances.<\/p> \u00a0<\/p>","url":"\/education-blog-153\/level-up-your-nutanix-skills-this-summer-and-get-a-free-exam-voucher-40952?postid=61291#post61291","creationDate":"2022-06-14T15:30:05+0000","relativeCreationDate":"1 month ago"},"contentType":"article","type":3,"likes":5,"hasCurrentUserLiked":false},"phrases":{"Forum":{"{n} year|{n} years":"{n} year|{n} years","{n} month|{n} months":"{n} month|{n} months","{n} day|{n} days":"{n} day|{n} days","{n} hour|{n} hours":"{n} hour|{n} hours","{n} minute|{n} minutes":"{n} minute|{n} minutes","just":"just now","{plural} ago":"{plural} ago"}}}">
\u00a0<\/h3>
Get started today!<\/a><\/h3>
Get a free certification exam when you complete a training course now through August 16! <\/strong><\/h3>
\u00a0<\/h3>
Get started today!<\/a><\/h3>
在多个VLAN之间拆分网络流量
我想知道是否有可能为每种不同流量类型的bellow具有不同的VLAN ID/子网范围:
- 管理程序管理(ESXI)
- Nutanix群集管理
- nutanix群集复制 /自动训练
最好的是,甚至对不同的VLAN进行复制和自动训练。
这里的理由是遵守有关DMZ虚拟化的客户内部安全策略。
我们被允许使用VLAN,并且不被迫使用不同的物理端口,但是安全团队(全球银行)担心ESXI和Nutanix在同一VLAN上。
西尔万。
\n
\nI was wondering if it's possible to have different VLANs ID\/Subnet range for each of the different traffic type bellow:
\n - Hypervisor Management (ESXi)
\n - Nutanix Cluster administration
\n - Nutanix Cluster replication \/ AutoPath
\n
\nAnd the very best would be to even have replication & AutoPath on different VLANs.
\n
\nThe rationale here is to comply with customer internal security policies regarding DMZ virtualization.
\nWe are allowed to use VLANs and are not forced to use differents physical ports, but the security team (worldwide bank) is concerned about the ESXi & Nutanix being on the same VLAN.
\n
\nSylvain.","quoteUsername":"shuguet","translations":{"Common":{"like":"Like","unlike":"Unlike"},"Forum":{"Quote":"Quote","Share":"Share"}}}">
5个答复
将HV/ESXI MGMT流量放在单独的VLAN上应该没问题(甚至在安装指南中提到)
至于“ Nutanix群集管理”和“复制流量”,我目前不支持它。
为什么?
如果在vlan-visor(vswitch)级别上进行VLAN-SPLITUP,则在CVM中需要第三/第四个VNIC(为其他网络配置附加的IP)
CVM运行的Linux当然没有问题,但是我看不到对不同NUTANIX服务的任何配置支持。
如果您“向前” VLAN标记了CVM内部的流量,并在VM内进行拆分,那仍然是同一问题。
我看到的唯一(理论上的)方式是使用10G键 - 键入CVM内部配置OpenVswitch。vNIC作为上行链路(带有标记的流量)和原始Nutanix CVM IP居住的本地VLAN。另外,还有一些“ openflow/openVswitch-rule” - 魔术(在这里变得棘手:P)标签,例如复制流量不同。
荒谬:-)
编辑:您可以发布到建议框 /产品功能 - 类别。
\nputting the HV\/ESXi mgmt traffic on a seperate VLAN should be no problem (its even mentioned in the install guide)
\n
\nas for the \"Nutanix Cluster Administration\" and the \"replication traffic\" i don't see it supported currently.
\n
\nWhy?<\/u>
\nIf doing the VLAN-Splitup on the Hypervisor(vSwitch)-Level, you would need a 3rd\/4th vNIC in your CVM (to configure the additional IPs for the additional networks)
\nWhich would be of course no problem for the Linux the CVM runs in, but i can't see any configuration support for the different Nutanix Services.
\n
\nIf you \"forward\" the vlan tagged traffic inside the CVM, and do the split-up inside the VM, it would still be the same Problem.
\nThe only (theoretical) way i see is to configure an openvswitch inside the CVM with 10g-bond-v<\/b><\/u>NICs as uplink (carrying tagged traffic) and a native VLAN of the primrary Nutanix CVM IP residency. In addition there is some \"openflow\/openvswitch-rule\"-magic (here it gets tricky :P<\/i>) which tags e.g. replication traffic differently.
\n
\nabsurd :-)
\n
\nEdit: you may post into the Suggestion Box \/ Product Features - category..","quoteUsername":"mluksch","translations":{"Common":{"like":"Like","unlike":"Unlike"},"Forum":{"Quote":"Quote","Share":"Share"}}}">
我很清楚UI的技术局限性,但是正如您所指出的那样,Linux VM对更加满意。
这只是添加该选项的问题,因此,如果现在不可能,我将接受您的建议并在建议部分中发布。
西尔万。
\n
\nIt's just a matter of adding the option, so if it's not possible right now, I will take your advice and post in the suggestion section.
\n
\nSylvain.","quoteUsername":"shuguet","translations":{"Common":{"like":"Like","unlike":"Unlike"},"Forum":{"Quote":"Quote","Share":"Share"}}}">
通常,您会将此参数用于CVM-IP-Addresses,但文档还谈论了理论(VPN)隧道地址。
对我来说,这看起来像您(至少从技术的角度来看)能够在CVM(以ESXI VSWITCH标记的其他VLAN(UN)中)添加第二个VNIC,并使用该IP进行复制流量。
(检查Cerebro服务是否在0.0.0.0上收听或界面是否绑定)
如果有效,nutanix可能会支持它。
我仍然想知道当时文档中的“隧道”评论。
\nNormally you would use this parameter for the CVM-IP-addresses, but the docs also talk about an theoretical (VPN) tunnel address.
\n
\nto me this looks like you would - at least from a technical point of view - be able to add a second vnic to the CVM (in a different vlan, (un)tagged by ESXi vSwitch), and use that IP for replication traffic.
\n
\n(check if cerebro service is listening on 0.0.0.0 or if it is interface bound)
\n
\nif that works nutanix will possibly support it.
\n
\nI'm still wondering about then \"tunnel\" comment in the docs.","quoteUsername":"mluksch","translations":{"Common":{"like":"Like","unlike":"Unlike"},"Forum":{"Quote":"Quote","Share":"Share"}}}">
描述
有时,网络设计需要CVM和ESXI主机在单独的网络上。电流版本的nutanix群集不允许使用此功能,并且HA.PY故障转移脚本无法正常运行。CVM网络中的地址分配给ESXI主机(除了CVM网络外主机上分配的主要管理地址外)。
解决方案
解决方法:
NCLI群集add-to-nfs-whitelist ip-subnet masks =“ x.x.x.x/n.n.n.n.n”
其中x.x.x.x是新的VMKernel端口组的IP地址,而N.N.N.N是子网罩。
\nSometimes a network design requires the CVMs and ESXi hosts to be on separate networks.Current versions of Nutanix cluster do not allow this, and the ha.py failover script will not function properly.A workaround is detailed below, however this still requires the use of addresses within the CVM's network to assign to the ESXi hosts (in addition to the primary management addresses assigned on the hosts outside of the CVM network).
\n
\nSolution<\/b>
\nWorkaround:
\n \n
\n
\n
\n
\nWhere x.x.x.x is the IP address of the new vmkernel port group and n.n.n.n is the subnet mask.
\n
由于第一种流量是管理(通常是路由/远程),第二种是存储(大部分时间L2,本地),因此将它们分成2个VLAN将很有意义。
西尔万。
\n
\nSylvain.","quoteUsername":"shuguet","translations":{"Common":{"like":"Like","unlike":"Unlike"},"Forum":{"Quote":"Quote","Share":"Share"}}}">